Astm D595798 Pdf [verified] Free
ASTM D5957-98 is the Standard Guide for Flood Testing Horizontal Waterproofing Installations. It provides a standardized methodology for testing the watertightness of horizontal surfaces—such as plaza decks and parking garages—by ponding water over a cured waterproofing system. Key Features of ASTM D5957-98
D5957 Standard Guide for Flood Testing Horizontal Waterproofing Installations
ASTM D5957-98 is a standard guide specifically for flood testing horizontal waterproofing installations. While it is technically a copyrighted document that requires purchase for a "clean" official copy, the technical core of the standard is widely used in construction reporting. ASTM International Summary: ASTM D5957-98 Guide ASTM D5957-98(2013)
Provides procedures for testing watertightness on horizontal surfaces with slopes of 2% or less, commonly applied to membranes before covering.
ASTM D5957-98, known as the Standard Guide for Flood Testing Horizontal Waterproofing Installations, is an essential industry guideline for verifying the watertightness of horizontal surfaces like plaza decks and parking garages.
While you can find summaries and technical data sheets referencing its procedures for free on sites like Laticrete or Intertek, the complete, official standard is copyrighted and must typically be purchased through the ASTM International website or Accuris Standards Store. Key Specifications of ASTM D5957-98 astm d595798 pdf free
The guide outlines the specific environment and technical requirements for a valid flood test:
Scope: It applies to horizontal surfaces with a slope no greater than 2% (1/4 inch per foot).
Water Depth: The test area should be flooded to a minimum depth of 1 inch and a maximum of 4 inches at the lowest point.
Duration: The water must be maintained for a minimum of 24 hours and a maximum of 72 hours.
Curing Time: Testing should not begin until at least 24 hours after the waterproofing system installation (or 48 hours if temperatures are below 50°F/10°C). ASTM D5957-98 is the Standard Guide for Flood
Structural Review: A licensed structural engineer must verify that the building can handle the added weight of the water before testing begins. Exclusions and Warnings
Not for Roofing: This standard specifically states it is not intended for use on building roofing systems.
Temperature Limits: It is not recommended for use if freezing temperatures are expected, as ice can damage the membrane or flashings.
Leak Protocol: If a leak is detected, the water must be drained immediately, repairs made, and the test repeated after the repairs have cured.
For those looking for a free alternative that follows these principles, technical bulletins like the Laticrete TDS-169 provide a practical, condensed version of the procedure for shower pans and horizontal applications. 1. ASTM Compass (Subscription)
Are you planning to perform a flood test on a specific project, like a balcony or a parking deck?
I understand you're looking for a free PDF of ASTM D5957-98 (Standard Guide for Flood Testing Horizontal Waterproofing Installations). However, I must begin with an important ethical and legal note before providing any content.
1. ASTM Compass (Subscription)
- Cost: ~$1,100/year for individual access (includes unlimited downloads)
- Best for: Firms that regularly access many standards
Complete Guide to ASTM D5957-98: Flood Testing Horizontal Waterproofing Installations
What Is ASTM D5957-98? (Overview)
Full Title: ASTM D5957-98 (Reapproved 2017) Standard Guide for Flood Testing Horizontal Waterproofing Installations
Published By: ASTM International, Committee D08 on Roofing and Waterproofing
Original Approval: 1998
Latest Reapproval: 2017 (no technical changes; reaffirmed as current practice)
Status: Active standard