Operating Systems: It is officially tested on original Microsoft media for Windows 10 Professional and Enterprise (32-bit and 64-bit).

Hardware (Recommended): For servers hosting HMI or Alarm and Event Tag services, Rockwell recommends a quad-core Intel Xeon 2.33 GHz or higher with at least 4 GB of RAM.

Virtual Memory: Ensure your disk space is sufficient to provide a virtual memory page file at least twice the size of your physical RAM. Critical Technical Considerations

Version Backwards Compatibility: FactoryTalk View Studio does not support simultaneous installation of different versions on one OS. Changes made in version 13 cannot be transferred back to older versions like v11.

Application Restoration: Version 13 users have reported difficulties restoring Network Station projects from older versions (like v10) if TLS and IIS settings are not correctly aligned during the upgrade process.

Data Server Connectivity: A known "Data Server is not available" error in v13 is often resolved by ensuring the Windows user/password of the client matches those of the server's Windows login. Key Resources for Implementation

Installation Guide: For step-by-step setup including post-installation actions and activation, refer to the official Installation Guide.

VBA & Server Configuration: In network distributed environments, complex server status monitoring often requires specific VBA code adjustments on lines 13-31 to point to the correct HMI and Data Servers.

Are you currently troubleshooting a specific error code or planning a system upgrade from an older version? FactoryTalk View Site Edition Installation Guide

FactoryTalk View Site Edition (SE) version 13 (v13) introduced several major features focusing on platform modernization, improved scripting, and simplified licensing Rockwell Automation Key New Features in Version 13 Client-Specific Tags

: Memory tags can now be scoped to individual client/user sessions. This allows you to drive operator-specific behavior (like unique navigation menus or object visibility) without affecting other active clients in a distributed system. Bi-directional PowerShell Scripting

: v13 expands the server-side scripting engine introduced in v12 to allow bidirectional data interaction. You can now write information back to HMI tags directly using PowerShell. New Visualization Objects XY Plot Object

: A specialized trend tool used to plot one tag value against another (rather than just vs. time), ideal for showing relationships between two sets of data. Data Grid Object : Allows users to display FactoryTalk View SE Data Log Models or Microsoft SQL data in a tabular, grid-based format. Modern Web Integration Web Browser object

now supports Microsoft Edge (Chromium-based rendering) in addition to Internet Explorer. .NET Control Support

: Developers can now import and use reusable custom .NET controls (Windows Forms and WPF) directly in HMI applications. Rockwell Automation Licensing and Commercial Changes factorytalk view se version 13

Starting with v13, Rockwell simplified its HMI licensing structure: Rockwell Automation Unlimited Displays

: All SE server bundles now include unlimited displays by default. Built-in Web Clients

: FactoryTalk ViewPoint web clients are now included for free. You no longer need to purchase separate ViewPoint licenses for v13 systems. Simplified Bundles

: Servers are offered in "Small" (5 clients), "Medium" (10 clients), or "Large" (25 clients) bundles, all with unlimited web clients. Rockwell Automation Installation and Setup Tips

FactoryTalk View Site Edition is HMI software ... - Release Note

FactoryTalk View SE version 13 focuses on operational efficiency and data connectivity, introducing several long-awaited objects and backend scripting improvements. The release also marked a shift in Rockwell's commercial model, bundling more features into standard server licenses. Key New Features

XY Plot Object: A specialized trend object that plots one set of tag values against another, allowing operators to analyze relationships between two variables over time rather than just time-based trends.

.NET Control Object: Supports reusable and custom Windows Forms and WPF controls, enabling developers to use third-party libraries or build bespoke UI elements directly in the HMI.

Data Grid Object: Allows users to display historical data log models and information from Microsoft SQL databases in a clean, tabular format.

Client-Specific Tags: New memory tags that are unique to each client and user session. This is particularly useful for building custom navigation menus or client-specific animations without complex scripting.

HMI Tag Synchronization: A new redundancy option that automatically synchronizes memory tag values between active and standby HMI servers to ensure consistency during a failover. System & Performance Enhancements

Chromium-Based Web Browser: The Web Browser object now supports Microsoft Edge (Chromium) as its rendering engine, moving away from the aging Internet Explorer standard.

Bi-directional PowerShell Scripting: Expands on previous versions to allow server-side PowerShell scripts to write data back to HMI tags, simplifying integration with IT systems and external data sources.

TrendPro Enhancements: Hovering over a line now displays the tag's caption instead of just the tag name, and new VBA properties support single-trace or stacked axis modes. Operating Systems : It is officially tested on

FactoryTalk System Status Portal: A web-based dashboard that provides an overview of all application servers (HMI, Alarm & Event, and Data) and their current status. Licensing & Bundling Changes Version 13 introduced a simplified pricing model:

Unlimited Displays: All server bundles now include unlimited displays by default.

Built-in ViewPoint: Activation is no longer required for FactoryTalk ViewPoint; unlimited web and mobile clients are included with every server and station bundle.

Server Bundles: Offered in Small (5 clients), Medium (10 clients), and Large (25 clients) packages to reduce the complexity of purchasing individual components. Hardware Requirements

For a computer hosting the HMI Server or Data Servers in a network application, Rockwell recommends: Processor: Quad-core Intel Xeon, 2.33 GHz or higher. RAM: 4 GB (minimum 2 GB).

If you are planning an upgrade, I can help with a migration checklist or detail the security changes regarding HMI Area Security—which ViewSE – v13: What's New In FactoryTalk View Site Edition

Rockwell recently released version 13.00 of FactoryTalk View Site Edition, and below I'll summarize the new and enhanced features, The Automation Blog

FactoryTalk View Site Edition Software - Rockwell Automation

Introduction to FactoryTalk View SE Version 13

FactoryTalk View SE (Software Engineering) version 13 is a powerful human-machine interface (HMI) software solution developed by Rockwell Automation. It provides a comprehensive platform for creating intuitive and interactive operator interfaces that enable efficient and effective control of industrial automation systems.

Key Features and Enhancements in FactoryTalk View SE Version 13

FactoryTalk View SE version 13 offers a range of exciting features and enhancements that improve the development, deployment, and maintenance of HMI applications. Some of the key features and enhancements include:

  1. Improved User Experience: FactoryTalk View SE version 13 provides a more intuitive and user-friendly interface, making it easier for operators to navigate and interact with the HMI.
  2. Enhanced Security: The software includes advanced security features, such as role-based access control, secure data storage, and encrypted communication, to protect against cyber threats.
  3. Increased Scalability: FactoryTalk View SE version 13 supports large-scale systems with thousands of tags, alarms, and trends, making it ideal for complex industrial automation applications.
  4. Improved Performance: The software features optimized performance, reducing the load time for large applications and improving overall system responsiveness.
  5. Expanded Connectivity: FactoryTalk View SE version 13 supports a wide range of communication protocols, including EtherNet/IP, ControlNet, and Modbus, enabling connectivity to various devices and systems.
  6. Enhanced Alarm Management: The software provides advanced alarm management features, including customizable alarm pages, audio alerts, and email notifications.
  7. Improved Data Analysis: FactoryTalk View SE version 13 includes enhanced data analysis capabilities, such as trending, historization, and reporting, to help operators and managers make informed decisions.

System Requirements for FactoryTalk View SE Version 13

To ensure smooth installation and operation of FactoryTalk View SE version 13, the following system requirements must be met: Improved User Experience : FactoryTalk View SE version

  1. Operating System: Windows 10 (64-bit) or later, Windows Server 2016 or later.
  2. Processor: Intel Core i5 or equivalent, 64-bit processor.
  3. Memory: 8 GB RAM or more, 2 GB free disk space.
  4. Graphics Card: DirectX 9 or later, 128 MB video memory.

Best Practices for Implementing FactoryTalk View SE Version 13

To maximize the benefits of FactoryTalk View SE version 13, follow these best practices:

  1. Plan and Design Carefully: Define clear goals, scope, and timelines for your HMI project.
  2. Develop a Comprehensive Architecture: Design a scalable and secure system architecture that meets your needs.
  3. Use Standardized Components: Leverage standardized components and templates to streamline development.
  4. Test Thoroughly: Perform rigorous testing to ensure the HMI application meets requirements and performs as expected.

Common Applications of FactoryTalk View SE Version 13

FactoryTalk View SE version 13 is commonly used in various industries, including:

  1. Process Industries: Chemicals, pharmaceuticals, oil and gas, food and beverage.
  2. Discrete Manufacturing: Automotive, aerospace, electronics, industrial equipment.
  3. Power Generation and Distribution: Power plants, substations, transmission and distribution systems.

Troubleshooting and Support for FactoryTalk View SE Version 13

If you encounter issues with FactoryTalk View SE version 13, refer to the following resources:

  1. Rockwell Automation Support: Contact Rockwell Automation support for assistance with installation, configuration, and troubleshooting.
  2. Online Resources: Utilize online resources, such as documentation, tutorials, and forums, to resolve common issues.
  3. Training and Certification: Consider training and certification programs to enhance your skills and knowledge of FactoryTalk View SE version 13.

By following this content, you should have a solid understanding of FactoryTalk View SE version 13 and be able to effectively implement and utilize the software in your industrial automation applications.

Here’s a professional write-up for FactoryTalk View Site Edition (SE) Version 13, suitable for a technical blog, release note summary, or internal company communication.


New or notable features in v13 (high‑level)

  • Improved compatibility and certification with the latest Logix controllers and Studio 5000 versions (ensure matching Rockwell compatibility charts).
  • Enhanced security options, including stronger authentication integration and clearer support for Windows Server/AD roles.
  • Performance and stability improvements for large distributed systems and multi‑monitor client deployments.
  • Updates to remote access and thin‑client/remote desktop scenarios; check release notes for supported RDP/VDI configurations.
  • Improved handling of tags, symbol renaming, and migration utilities from prior FactoryTalk View SE versions.

2. Performance Optimizations for Large-Scale Applications

Engineers managing extensive distributed systems will notice faster client startup times and reduced network bandwidth usage. Improvements include:

  • Optimized HMI tag server communication, reducing latency in high-tag-count projects.
  • Enhanced display caching for repeated graphic windows, cutting load times by up to 30% in internal tests.
  • Better handling of trend and alarm history queries through refined database access logic.

5. Development Environment Productivity Boosts

The Studio SE development environment includes:

  • A searchable Global Object Definition panel for faster reuse of standard graphics.
  • Parameter file validation that checks for missing or mismatched parameters before runtime.
  • Tag browser filters by data type, folder, or alias status, streamlining navigation in large databases.

9. Licensing – The Silent Change

Version 13 enforces FactoryTalk Activation Manager 5.0 (no more legacy EVRSI). Concurrent user licenses now check out every 90 minutes instead of 7 days – ensure your activation server is on a low-latency network. Offline grace period reduced to 14 days (from 30 in v11).

3. Distributed Architecture – Display Cache Behavior Overhaul

In previous versions, network-distributed displays (clients loading from a remote SE server) used an aggressive local cache. V13 introduces conditional display caching:

  • Displays > 5 MB are streamed incrementally (reduces initial load time by ~40% on 100 Mbps networks)
  • However, animation data binding now uses WebSocket compression – ensure firewalls allow port 58725 (TCP) for real-time tag updates

Watch out: If you use Display /Replace command frequently, the new cache invalidation can cause flicker. Fix by setting [Cache]DisplayLifetime=30000 (milliseconds) in the FTViewSE.ini file on each client.

Hol dir jetzt die fernsehserien.de App