Regia di Danny Leiner vedi scheda film
Installing a Wella Climazon Millenium is a critical task for any modern salon seeking to provide high-end color, permanent wave, or care treatments. Proper installation ensures the safety of your staff and clients while maximizing the longevity of this sophisticated infrared hair processor.
This guide provides a comprehensive overview of the manual installation process for both the pedestal and wall-mounted versions of the Climazon. 1. Pre-Installation: Choosing Your Configuration
The Wella Climazon Millenium typically comes in two primary configurations:
Pedestal (Mobile) Version: Ideal for salons that need to move the device between different styling stations.
Wall-Mounted Version: Best for saving floor space, using the Acrobat 2004 wall arm (Type WA04/75 or WA04/95). 2. Pedestal Version Installation Steps
The mobile unit is mounted on a height-adjustable stand with rollers (typically the ST5 tripod).
Assemble the Base: Secure the tripod feet (Type ST5) with the rollers provided.
Insert the Tripod Tube: Fit the tripod tube (Type ST5) into the base and ensure it is tightened according to the manual.
Attach the Appliance Head: Carefully place the Climazon head onto the tube. Secure it using the cable holder, which doubles as a safety lock to prevent the head from detaching.
Connect Power: Route the power cable through the designated cable holder and plug it into a standard grounded outlet. 3. Wall-Mounted Version Installation Steps
Installing the wall-mounted version requires structural verification of your salon wall to ensure it can support the weight and movement of the Acrobat wall arm.
Mount the Wall Bearing: Fix the wall bearing (Type WL04) to the wall at the recommended height.
Attach the Extension Arm: Slot the boom (extension arm) into the wall bearing. Ensure the brake screws are adjusted to allow smooth but controlled movement.
Install the Spring Arm: Attach the spring arm (Type WA04) to the boom. This component allows for vertical height adjustment.
Calibrate Load Capacity: Use the adjustment opening on the spring arm to set the load capacity. This ensures the device stays at the desired height without drifting up or down.
Final Security: Attach the protective caps to the arm joints to protect against electrical shock and mechanical pinching. 4. Technical and Electrical Setup
Power Supply: Ensure your salon’s electrical system matches the device's requirements. Both versions include a country-specific mains plug.
Temperature Sensor: Before first use, verify the temperature sensor (located in the center of the head) is fitted with its protective filter to prevent contamination.
Language Settings: Upon first powering on, use the SETTING button to navigate the menu and select your preferred language (the device supports up to 18 languages). 5. Post-Installation Safety Check Before treating your first client, perform a test run:
Ensure all five heating elements move freely and lock into their three standard positions.
Test the "Customer Button," which allows the client to manually lower the temperature for comfort.
Check that the air vents for the heating elements are unobstructed.
For detailed technical diagrams and specific torque settings, you should download the official Climazon Manual from the Wella Professionals Website.
Setting Up Success: A Guide to the Wella Climazon Millennium Installation Wella Climazon Millennium (often referred to as the
) is a cornerstone of modern salon technology, designed to speed up processing times for color and treatments. Whether you are setting up a brand-new salon or upgrading your equipment, installing this high-precision infrared processor correctly is vital for safety and performance. Wella Professionals Pre-Installation Checklist Before you begin, identify your specific model. The generally comes in two versions: Pedestal (Stand) Version : Uses the ST5 Pedestal , which includes a three-roller base and a support tube. Wall-Mounted Version : Requires the Acrobat 2004 Wandarm (Type WA04/75 or WA04/95). Wella Professionals Step-by-Step Installation Guide 1. Mount the Support Structure For Pedestal Units : Secure the appliance head into the Stativ ST5 stand. Ensure the cable holder
is utilized to secure the power cord, preventing tripping hazards or accidental disconnection. For Wall Units
: The installation must be performed by qualified personnel. Approved variants include Acrobat 2004 wall bearings, ceiling mounts (DB04/2), or floor mounts. Wella Professionals 2. Power Connection Ensure the main ON/OFF switch is in the "OFF" position before plugging in. Connect the unit to a grounded wall power supply. Safety Warning
: If installing a wall-mounted arm, keep protective caps in place to prevent electric shock from live plug connections. Wella Professionals 3. Adjusting the Heating Elements Climazon Millennium
features five infrared heaters designed for precise heat distribution Wella Professionals
: These are foldable and can be set in three different positions to accommodate different hair lengths and styles. Sensor Calibration : Ensure the temperature sensor
, located behind a protective filter, is unobstructed to allow the unit to monitor heat accurately. Wella Professionals 4. Final Safety & Function Test Check Ventilation
: Ensure the ventilation openings for radiator waste heat are clear. Test the "Customer Button"
: This allows clients to manually lower the treatment temperature for comfort—the indicator will turn blue when the temperature is lowered. Monitor for Errors : Upon startup, check the display. If you see codes like (temperature measurement) or (heating won't switch off), consult the Climazon2 Troubleshooting Manual immediately. Wella Professionals Essential Documentation
For detailed diagrams and technical specifications, refer to the official Installation PDF Acrobat 2004 Wallarm Manual provided by Wella Professionals to keep your running efficiently?
Before you physically mount the dryer, verify the following. Ignoring these steps is the #1 cause of warranty voidance and electrical failure.
To guide technicians or salon owners through a tool-based, manual installation of the Wella Climazon Millenium hood dryer when the original wall/ceiling bracket is missing, damaged, or when using a third-party stand.
Comprehensive Installation Guide for the Wella Climazon Millenium
The Wella Climazon Millenium (often referred to in technical documentation alongside the Climazon²) is a cornerstone of professional salon equipment, offering precision infrared heating for coloring, perming, and drying treatments. Proper installation is critical to ensure both the safety of your clients and the longevity of the device.
This guide outlines the manual installation process for the two primary configurations: the Pedestal (mobile) version and the Wall-Mounted version. 1. Safety and Pre-Installation Requirements Before beginning, ensure you have a suitable environment.
Professional Requirement: Wall-mounted versions must be installed by a qualified specialist (electrician or technical expert) to ensure secure fixing and correct electrical wiring.
Compatibility Warning: Never use the Climazon Millenium with older Wella pedestals (such as type ST3), as the device may fall and cause injury.
Space Management: Ensure the area allows for the movement of the side heating arms, which are adjustable and foldable. 2. Pedestal (Mobile) Installation: Step-by-Step The mobile version typically utilizes the ST5 Pedestal. Phase A: Assembling the Base
Castor Attachment: Push the three swivel castors into the pre-drilled holes on the underside of the pedestal base until they click into place. Ensure they are secure to prevent the unit from tipping.
Tube Preparation: Unscrew the extension locking screw from the pedestal tube. Warning: The internal spring may cause the tube to extend slowly; ensure no people or objects are directly in front of it.
Secure the Tube: Align the tube vertically with the base plate. Insert it and tighten the locking screw from the underside of the base until the tube is firmly immobilized. Phase B: Mounting the Device Head
Alignment: Lift the Climazon head and align its mounting point with the top of the pedestal tube.
Locking Mechanism: The device often features an internal locking latch. Ensure the head is pushed down until it "clicks." You can verify the lock by attempting to lift it gently without using the release mechanism.
Cable Management: Use the integrated cable holder (standard on ST5 models) to secure the power cord, preventing tripping hazards during salon use. 3. Wall-Mounted Installation: Step-by-Step
Wall installation requires the Acrobat 2004 (WA04) wall arm or similar approved support. Phase A: Fixing the Wall Bracket
Wall Assessment: Determine if the wall is solid masonry or reinforced studs. Use the Acrobat 2004 manual to verify load-bearing requirements.
Mounting: Align the mounting bracket and mark the drill holes. Insert heavy-duty wall anchors and secure the bracket with the provided high-tensile screws. Phase B: Attaching the Arm and Head
Arm Assembly: Insert the extension arm into the wall bracket. Attach the spring arm (Acrobat) to the extension arm. Caution: The spring arm is under high tension and should only be released once the weight of the Climazon head is attached.
Head Installation: Slide the Climazon head onto the pin at the end of the spring arm. Ensure the safety screw or locking pin is fully engaged to prevent accidental detachment.
Adjustments: Use the brake screws on the arm to adjust the swivel resistance and the internal tension screw to balance the vertical movement based on the head's weight. 4. Technical Maintenance and Resources
Error Codes: If the operating lights blink, refer to the Wella Climazon² troubleshooting guide.
Manual Downloads: For specific technical drawings or parts lists (like the S31 model), you can often find them on repositories like ManualsLib or Wella Professionals.
A useful feature of the Wella Climazon² (often referred to as the Millenium in some markets) is its adaptable heating architecture, which utilizes five adjustable infrared heating elements that allow for targeted treatment delivery. Key Features for Installation & Setup
When installing or configuring the unit, these manual features provide significant versatility:
Moveable Side Arms: The side arms are foldable and the side heaters are adjustable into three different positions, allowing you to tailor the hood-like drying effect to the specific head shape or hair length of a client.
Mounting Flexibility: The device can be installed in several configurations depending on your salon space, including a pedestal version (ST5 tripod base) or various wall and ceiling mounts using the Acrobat 2004 wall arm system.
Adjustable Height & Tension: For wall-mounted installations, the Acrobat 2004 wall arm includes openings to manually set the height stop and the load capacity (tension), ensuring the arm stays exactly where you position it.
Customer Temperature Control: The unit includes a "Customer Button" that allows the client to manually lower the treatment temperature themselves for personalized comfort.
Specialized Program Modes: The software includes dedicated settings for different chemical processes (Color, Perm, Care, or Drying) that can reduce treatment time by up to 33% compared to standard drying.
For detailed installation steps and safety specifications, you can refer to the official Climazon² User Manual. Climazon | Hood Hair Dryer - Wella Professionals
The unit uses a 3-core cable (Live, Neutral, Earth/Ground).
Before installing the Climazon Millennium, verify these electrical specs. Incorrect power will destroy the control board.
Before commencing installation, the following safety protocols must be strictly observed: